1.
J Pers Med ; 13(12)2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38138915

RESUMO

Treating individuals with single-sided deafness (SSD) with a cochlear implant (CI) offers significant benefits for speech perception in complex spatial listening environments. After implantation, training without involvement of the normal-hearing ear is essential. Therefore, the AudioLink streaming device (MED-EL GmbH, Austria) can be used to connect the externally worn audio processor to media devices; thus, the auditory stimuli are directly streamed to the implanted ear. The aim was to test whether children with SSD, aged 5-12 years, accept this training method and whether auditory training, streamed directly via AudioLink using the Tiptoi device (Ravensburger GmbH., Ravensburg, Germany), improves speech recognition. A total of 12 children with SSD and implanted with a CI received Tiptoi training via AudioLink and were asked to practice daily for 10 min over a period of one month. All participants completed the training. The measurements employed to assess improvement included speech audiometry, speech, spatial, and quality of hearing scale for parents (SSQ P), and specially designed tasks crafted for this study. Daily training of 9.93 min was reported. The word recognition score (WRS) at 65 dB and 80 dB in aided condition significantly improved and the WRS streamed via AudioLink was significantly better after training. The speech, spatial, and qualities of hearing scale for parents (SSQ P questionnaire) showed significant improvement in the dimension of quality of hearing and overall gain. The outcomes of the Tiptoi tasks resulted in a significant benefit in both categories of the "recognition of sounds" and "understanding of sentences". The results are very encouraging and do not only show the positive uptake of daily training at home but also how this resulted in a significant improvement in subjective and objective measures for this rather short training period of one month only.

2.
Audiol Neurootol ; 27(2): 175-183, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34044387

RESUMO

OBJECTIVE: The study shows the long-term effectiveness, safety, and quality of life after Vibrant Soundbridge (VSB) implantation in sensorineural hearing loss (SNHL) using the short process coupler (SP) or the long process coupler (LP). METHODS: This retrospective study evaluated 77 VSB cases. Follow-up (F/U) time-dependent objective measurements (audiological outcomes), subjective data collection (quality-of-life questionnaire), and safety measures are presented. RESULTS: Sixty-two ears were included in the analysis with up to 116 months of postsurgical F/U data (mean 32.15 ± 37.97 months LP and SP coupler). Fifty-three ears (13 bilateral cases) received the LP coupler and 9 subjects the SP coupler. The post-operative bone conduction thresholds remained stable and, in both groups, <10 dB. The benefit in word recognition scores measured at 65 dB SPL and 80 dB SPL showed no significant difference between the couplers (p = 0.559 and p = 0.088, respectively). The functional gain was not significantly different (p > 0.05) with a mean of 20.91 ± 9.77 and 17.19 ± 5.75 for LP and SP coupler, respectively. The utility score deciphered from the Assessment of Quality-of-life Questionnaire-8 dimensions revealed a mean score of 0.75 ± 0.16 which is not significantly different to the age- and sex-matched healthy control group with 0.81 ± 0.02 (p = 0.3547). CONCLUSION: The Incus Vibroplasty utilizing both couplers is a safe and effective method to treat mild-to-severe SNHL. Both fixation methods of the floating mass transducer exhibit good clinical and audiological outcomes with high patient quality of life. The SP coupling method can be a good alternative when the long process is anatomically inaccessible, or the approach is limited due to anatomical reasons.


Assuntos
Perda Auditiva Condutiva-Neurossensorial Mista , Perda Auditiva Neurossensorial , Prótese Ossicular , Perda Auditiva Neurossensorial/cirurgia , Humanos , Bigorna , Qualidade de Vida , Estudos Retrospectivos , Resultado do Tratamento
3.
Laryngoscope ; 131(5): E1434-E1442, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33210744

RESUMO

OBJECTIVE: The objective of the study was to demonstrate the long-term outcomes of patients implanted with the active middle ear implant (AMEI) Vibrant Soundbridge (VSB) through coupling the floating mass transducer (FMT) to the round window (RW). METHODS: This retrospective study evaluated the short- and long-term clinical performance (audiological outcomes) and safety (revisions/explantations) of the VSB coupled to the RW between 2013 and 2019 at the St. Pölten University Hospital, Austria. For the outcome analysis, the sample was divided into a short-term examination group followed up for less than 12 months (<12 months) and a long-term examination group followed up for more than 12 months (>12 months). Cumulative survival outcomes were separately analyzed for subjects with and without cholesteatoma. RESULTS: 46 patients with an average long-term follow-up period of 31.43 months (13-75 months) were investigated. Complications requiring revision surgery were reported in total in seven patients with cholesteatoma (15.2%) and none in subjects without cholesteatoma (0%). Residual hearing was not affected by VSB surgery. Word understanding on the Freiburger monosyllabic speech test improved significantly at 65 dB (P < .0001) and 80 dB (P < .0001), and these outcomes were stable for long-term follow up. CONCLUSION: The VSB coupled to the RW is a safe implantation method for patients with conductive or mixed hearing loss. Hearing improvement was stable for the long-term follow-up up to 74 months. The revision rates are directly related to the underlying pathology of cholesteatoma (with radical cavity); thus, this special cohort requires additional counseling on potential complications. LEVEL OF EVIDENCE: 4 (Case-series) Laryngoscope, 131:E1434-E1442, 2021.


Assuntos
Colesteatoma da Orelha Média/cirurgia , Perda Auditiva Condutiva/cirurgia , Perda Auditiva Condutiva-Neurossensorial Mista/cirurgia , Substituição Ossicular/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Janela da Cóclea/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Áustria/epidemiologia , Colesteatoma da Orelha Média/complicações , Remoção de Dispositivo/estatística & dados numéricos , Feminino , Seguimentos , Perda Auditiva Condutiva/diagnóstico , Perda Auditiva Condutiva/etiologia , Perda Auditiva Condutiva-Neurossensorial Mista/diagnóstico , Perda Auditiva Condutiva-Neurossensorial Mista/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Prótese Ossicular/efeitos adversos , Substituição Ossicular/instrumentação , Substituição Ossicular/métodos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS